Every experienced miner knows the drill: lock out, tag out and then try it. But veteran crews also know the harder truth. Pulling the disconnect removes one kind of energy, but it doesn't always remove the rest.
For example, MSHA's belt-conveyor guidance tells miners to identify, isolate and control four (4) kinds of stored energy: mechanical, electrical, hydraulic and gravitational.
Its Lock-Tag-Try alert goes even further and lists seven (7) kinds of energy, adding pneumatic, chemical and thermal to the list. Lockout handles the electrical source, but the rest can still be right there, sitting in the machine, waiting.
Examples of Energy That Can Outlast the Shutdown
Mechanical: A tensioned conveyor belt is a stretched spring. MSHA advises relieving tension at the take-up, and warns that some tensile energy may remain even then. Don't use belt grippers on a tensioned belt; use properly rated, engineered clamps and come-alongs anchored to substantial structure, set at 90 degrees to belt travel.
Hydraulic: A cylinder holding up a bucket, bed or boom is not a support. MSHA's rule is blunt: never depend on hydraulics to support a load, and verify that all stored energy is released before starting repairs.
Gravitational: Anything raised wants to come down. MSHA training guidance says blocking is required whenever any possibility of non-powered movement exists. Federal coal standards (30 CFR 75.1726(b) and 77.405(b)), which apply specifically to coal mines, prohibit work under raised equipment until it's securely blocked in position — with blocking material MSHA describes as "competent, substantial and adequate" for the load.
Electrical: Even this one has traps. MSHA says to lock out at the main or circuit power source — not at on/off switches, interlocks, emergency stops or selector switches. A belt's start and stop controls, for example, don't disconnect the power conductors. For electrical work, MSHA's arc-flash guidance goes further: open the visual disconnect to confirm incoming power is off. Then lock and tag that visual disconnect and ground the de-energized conductors. Finally, test to confirm there's no power.
How to Stay "Energy-Mindful" While Working
- Ask "What can happen?" first. Run a risk assessment that evaluates pivot points before work begins.
- Make procedures machine-specific. A generic checklist won't show every energy source on every machine. For non-routine jobs like adding or removing a belt, write the steps down and review them with every miner first.
- One person, one lock. Every miner uses a personal, unique lock and tag — no duplicate locks or keys.
- Use group lockout for complex jobs. When a job involves multiple miners, machines, or energy sources, MSHA says clearly defined group lockout procedures may be used.
- Plan for the block to fail. Know what moves if a clamp or block lets go, and stand clear of its path.
- Communicate before restart. Confirm everyone is clear, and tell the crew before your lock comes off.
Zero energy isn't the moment the power goes off. It's the moment you've proven that every source — mechanical, electrical, hydraulic, gravitational and the rest — is fully under control.